We manufacture various elements of building developments that play the role of compartmentation of fire zones and allow for appropriate conditions of staff evacuation. Fire-resistant ironworks include aeration doors, smoke vents, permanent partition walls, post and beam facades, glass roofs and technical windows. Depending on clients’ needs, our constructions can have fire resistance class from EI15 to EI120 and glass roofs – REI20/RE30.

GALLERY PROJECT

 

SMOKE VENTS

The installation of smoke vents is particularly important in buildings where many people stay. Thanks to smoke vents, the heat accumulated during a fire inside the building is quickly discharged outwards, which facilitates evacuation.

 

AERATION DOORS

Aeration of the interior of the building is a necessary operation of efficient fire systems and smoke exhaust installations, i.e. removal of heat, hot air and toxic gases that gather during a fire from passageways and staircases. The provision of an appropriate volume of fresh air is necessary to ensure safety of people staying in the building.

 

SMOKE EXHAUST AND AERATION WINDOWS

Alsal is a manufacturer of automatically-opened smoke exhaust, aeration and ventilation windows. For manufacturing of these elements we use mainly profiles of insulated window systems equipped with electric servo-motors of renown manufacturers. The number of moto-servers and their types are selected depending on the required area of smoke exhaust, size, shape and location of the window.

Depending on the criteria of product classification and the function that the product is to fulfill, ALSAL has different types of windows in its offer:

  1. Way of opening:
    o Awning windows open outward
    o Awning windows open inward
    o Tilt windows open inward
    o Casement windows open outward
    o Casement windows open inward
  2. Thermal requirements:
    o No requirements
    o Standard requirements
  3. Acoustic requirements:
    o No requirements
    o With increased acoustic requirements

At the same time, elements manufactured by us take into consideration the requirements of relevant standards and regulations concerning:

  1. Resistance to wind load
  2. Air permeability
  3. Fire retardation
  4. Watertightness
  5. Impact resistance
  6. Acoustic properties
  7. Heat permeability
  8. Strength requirements
  9. Resistance to weather influences

FIRE-RESISTANT ROOF COVERINGS

Alsal is a manufacturer of glass roof coverings based on post and beam facades of ei fire-resistance. For manufacturing of these elements we use special facade profiles with an appropriate number of special inserts that decide about fire-resistance of aluminium elements in accordance with the guidelines of product documents. Elements of ei fire resistance are manufactured and assembled strictly as per technical approvals and guidelines of the building research institute for these elements.

 

The maximum allowed sizes of elements of fire resistance, construction divisions, type and thickness of fillings, etc. are strictly defined by relevant documents (technical approvals, etc.).

Each element of EI fire resistance is smoke-tight.

Depending on the criteria of product classification and the function that the product is to fulfil, ALSAL has different types of glass roof coverings in its offer:

Fire resistance class:
REI 20
EI 30
Thermal requirements:
No requirements
Standard requirements
At the same time, elements manufactured by us take into consideration the requirements of relevant standards and regulations concerning:

Resistance to wind load
Resistance to snow load
Air permeability
Fire retardation
Watertightness
Impact resistance
Acoustic properties
Heat permeability
Strength requirements
Resistance to weather influences

 

FIRE-RESISTANT POST AND BEAM FACADES

For manufacturing of these elements we use – both for external and internal elements – special facade profiles with an appropriate number of special inserts that decide about fire resistance of aluminium elements in accordance with the guidelines of product documents. Manufacturing and assembling of elements of EI fire resistance takes place strictly as per technical approvals and guidelines of the Building Research Institute for these elements.

The maximum allowed sizes of fire resistance elements, construction divisions, type and thickness of fillings, etc. are strictly defined by relevant documents (technical approvals, etc.).
Each element of EI fire resistance is smoke-tight.
Depending on product classification criteria and functions it is to fulfil, ALSAL has the following post and beam facades in its offer:

Fire resistance class of curtain walls:
• EI 15
• EI 30
• EI 45
• EI 60

Architectural form
• EI post and beam façade with external pressure and masking strips holding glass (visible from the outside)
• EI post and beam façade without external pressure and masking strips (only glass and silicon visible from the outside) – interspaces between individual glass forms are filled with special silicon.

Thermal requirements:
• No requirements
• Standard requirements

At the same time, elements manufactured by us take into consideration the requirements of relevant standards and regulations concerning:

1. Resistance to wind load
2. Air permeability
3. Fire retardation
4. Watertightness
5. Impact resistance
6. Resistance to weather influences
7. Strength requirements
8. Heat permeability
9. Acoustic properties

 

FIRE- RESISTANT FRAMES, DOORS AND WINDOWS

 

Alsal is a manufacturer of many different types of fire- resistant external and internal frames, doors and windows of ei fire resistance. For manufacturing of these elements we use – both for external and internal elements – special insulated profiles with an appropriate number of special inserts that decide about fire-resistance of aluminium elements as per the guidelines of the product documents.

 

Elements of EI fire resistance are manufactured and assembled strictly as per technical approvals and guidelines of the Building Research Institute for these elements.

The maximum allowed sizes of fire resistance elements, construction divisions, type and thickness of fillings, etc. are strictly defined by relevant documents (technical approvals, etc.).

In its offer, ALSAL has different types of frames, doors and windows, depending on the criteria of product classification and the function that the product is to fulfil. Each element of EI fire resistance is smoke-tight.

Fire resistance class:
•EI 15 – doors, frames, fixed windows, technical widow
•EI 30 – doors, frames, fixed windows, technical widow
•EI 45 – doors, frames, fixed windows, technical widow
•EI 60 – doors, frames, fixed windows, technical widow
•EI 90 – doors, frames, fixed windows, technical widow
•EI 120 – frames, fixed windows
Architectural form:
•Frames, fixed windows with bolections (casing + mullion-transom profiles + filling)
•Frames, fixed windows without bolections (casing + filling) – this type has no walls
Thermal requirements:
• No requirements
• Standard requirements
Way of door opening:
• Casement doors open inward
• Casement doors open outside
• Sliding
Evacuation requirements:
•No requirements
•Evacuation
•Anti-panic
Acoustic requirements:
• No requirements
• With increased acoustic requirements
At the same time, elements manufactured by us take into consideration the requirements of relevant standards and regulations concerning:

Resistance to wind load
Air permeability
Fire retardation
Watertightness
Impact resistance
Acoustic properties
Heat permeability
Strength requirements
Resistance to weather influences
Mechanical durability of external doors

en_USEnglish